CM Box User GuideMain Page | About | Special pages | Log in

Printable version | Disclaimer | Privacy policy | Current revision

(Difference between revisions)

Revision as of 10:05, 4 August 2006
Peter (Talk | contribs)
('''Chapter 11. Development of ET<sub>0</sub> computation procedure.''')
← Previous diff
Revision as of 10:06, 4 August 2006
Peter (Talk | contribs)

Next diff →
Line 61: Line 61:
|width="225"|Specify the lay-out of the file to AgrometShell with the following screen|| [[Image:graph26.jpg|500px|]] |width="225"|Specify the lay-out of the file to AgrometShell with the following screen|| [[Image:graph26.jpg|500px|]]
|---- |----
-|width="225"|View the results|| [[Image:graph27.jpg|500px|]] +|width="225"|View the results. Notice the reference ET column (column 6)|| [[Image:graph27.jpg|500px|]]
|} |}
</blockquote> </blockquote>

Revision as of 10:06, 4 August 2006

Chapter 11. Development of ET0 computation procedure.

Potential evapotranspiration (ET0) is a vital input to Water Balance calculations, which in turn are a vital part in Crop forecasting. The parameters needed to calculate ET0 are the following:

Parameter group Parameters Remarks
Temperature Maximum and minimum temperature Some ET0 calculation methods use average temperature only. AgrometShell needs both minimum and maximum temperatures.
Radiation (MJ/m2) Global radiation Global radiation can be calculated from sunshine hours or sunshine fraction accompanied by latitude and day in the year (Julian Date).
Wind Speed (m/sec) Wind speed at 2 meters Formulas are available to convert wind speed for other heights (e.g. 10 meters) into a 2 meter value.
Optional: relative humidity (%) Maximum and minimum relative humidity during the day. Although this parameter is not essential it improves the ET0 calculations substantially. In AgrometShell relative humidity can be calculated from vapour pressure measurements.


Checking data availability in AgrometShell

In AgrometShell activate the Tools – Potential ET – Manual function.

The manual ET0 calculation window

On the left side the input parameters are specified. On the right side, the outcome is generated, once the Calculate>> button is pressed. Clear the parameters on the left side of the screen and fill them with your own data. Try to calculate. If a value is calculated for the ET0, the top right value (Reference ET) is filled. The From… buttons make it possible to calculate the following parameters in an alternative way:

  • Day number in the year
  • Global radiation
  • Vapour pressure

Calculating ET0 using external ASCII files.

The ET0 calculations can be done in AgrometShell using data from the database or data in external ASCII files. In this paragraph the second option will be outlined.

The input file should be in FAO format. You can check this by displaying the file with the View – Data – As columns function
Display the FAO format file in the Agrometshell Viewer. The headers explain the data prevalent in the columns.
Now activate the Tools-Potential ET-From file function
Specify the lay-out of the file to AgrometShell with the following screen
View the results. Notice the reference ET column (column 6)